Directive 89/686/EEC
Category I Minor risks
Category II Reversible risks
(injury), certified compliant by a notified body.
Category III Irreversible risks
(corrosion), certified compliant and tested by a notified body whose number is specified.
General Requirement
The user can consult the instruction for use.
Chemical Protection and Micro-organism
EN374-1 (terminology and performance requirement)
EN374-2 (resistance to penetration)
EN374-3 (resistance to permeation by chemicals)
Mechanical Protection
Test | Performance Level | ||||
---|---|---|---|---|---|
1 | 2 | 3 | 4 | 5 | |
a) Abrasion resistance (cycle) | >100 | >500 | >2000 | >8000 | - |
b) Blade cut resistance (index) | >1.2 | >2.5 | >5 | >10.0 | >20.0 |
c) Tear resistance (newton) | >10 | >25 | >50 | >75 | - |
d) Puncture resistance (newton) | >20 | >60 | >100 | >150 |
Micro-organisms Resistance Glove
Assess by: Air leakage test or water filling test
AQL Level | 1 | 2 | 3 | AQL ≥ 2 |
4.0 | 1.5 | 0.65 |
Low Risk Chemical Protection Glove
Assess by: Water leak test Water proof but not passing the level required for high risk chemical protection glove.
Low Risk Chemical Protection Glove
Assess by: Chemical permeation test
Breakthrough times more then 30mins (levels 2) for a minimum of 3 specific chemical listed below and water proof. Therefore the letter code of the chemicals can be more than 3 letters and up to 12.
Code | Chemical |
---|---|
a | Methanol |
b | Acetone |
c | Acetonitrile |
d | Dichloromethane |
e | Corbon disulpide |
f | Toluene |
g | Diethylamine |
h | Tetrahydrofurane |
i | Ethyl acetate |
j | n-Heptate |
k | Sodium hydroxide 40% |
L | Sulphuric acid 96% |
Cold Protection
Test | Performance Level | ||||
---|---|---|---|---|---|
0 | 1 | 2 | 3 | 4 | |
a) Resistance to convective cold | I > 0.1 | 0.1 < I < 0.15 | 0.15 < I < 0.2 | 0.22 < I < 0.3 | 0.3 < i |
b) Resistance to contact cold | R < 0.025 | 0.025 < R < 0.05 | 0.05 < R < 0.1 | 0.1 < R < 0.15 | 0.15 < R |
c) Permeability to water | Fail | Pass |
(*Fail: water penetrated after 30min; Pass: no water penetrated after 30min)
Welding Glove
Combination from testing of EN407 And EN388 Type A glove - higher protection against heat Type B glove - lower protection against heat but are more flexible and pliable
Thermal Risk Protection
Assess by: Air leakage test or water filling test
Test | Performance Level | ||||
---|---|---|---|---|---|
1 | 2 | 3 | 4 | ||
a) Burning behavior | ≤ 20 | ≤ 10 | ≤ 3 | ≤ 2 | |
after burn (Times sec) | |||||
after glow (Times sec) | N/R | ≤ 120 | ≤ 25 | ≤ 5 | |
b) Contact heat (Temp in °C after 15 sec) | 100 | 250 | 350 | 500 | |
c) Convective heat (heat transfer delay sec) | ≤ 4 | ≤ 7 | ≤ 10 | ≤ 18 | |
d) Radient heat (heat transfer delay sec) | ≤ 5 | ≤ 30 | ≤ 90 | ≤ 150 | |
e) Small splashes of molten metal (drop) | ≤ 5 | ≤ 15 | ≤ 25 | ≤ 35 | |
f) Large splashes of molten metal (g) 30 | ≤ 30 | ≤ 60 | ≤ 120 | ≤ 200 |
Thermal Risk Protection
Assess by: Air leakage test or water filling test
Category (Y) | Addition Requirement |
---|---|
A | Acid resistance |
H | Oil resistance |
Z | Ozone resistance |
M | Resistance against high mechanical strain |
R | Oil, Ozone and high mechanical strain |
C | Resistance against extreme cold |
Class (X) | Tested at Voltage | Approved for work under voltage |
---|---|---|
00 | 2500 | ≥ 500 |
0 | 5000 | ≥ 1000 |
1 | 10000 | ≥ 7000 |
2 | 20000 | ≥ 17000 |
3 | 30000 | ≥ 26500 |
4 | 40000 | ≥ 36000 |